Seitenansicht 0
Scalable Fixtures (ERS3 & ERS4)
Evolve
LED Roadway Light
BEFORE YOU BEGIN
Read these instructions completely and
carefully.
Save these instructions for future use.
WARNING
Risk of electrical shock. Disconnect power before servicing
or installing product.
GE
Lighting
Installation Guide
GEH-6012B
imagination at work
SPECIFICATIONS
Weight: Maximum weight
ERS3 - ERS4: 40 to 46 lbs. (18.14 to 20.87 kg.)
IP Rating: Optical IP65, Standard Electrical Enclosure:
UL 1598 Wet Location Rated
Dimensions: L x W x H
ERS3 - ERS4: 37.3 in. x 15.0 in. x 5.4 in.
(947mm x 380mm x 137mm)
IEC Fixture Rating: IP44
Mounting Height: 27 - 40 ft. (8.2m - 12.2m)
EPA:
ERS3- ERS4 : 1.0 ft
2
CAUTION
Risk of injury. Wear safety glasses and gloves during
installation and servicing.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
This luminaire is designed for outdoor lighting service,
and should not be used in areas of limited ventilation,
or in high ambient temperatures.
Best results will be obtained if installed and maintained
according to the following recommendations.
Luminaire is designed to operate in ambient
temperatures ranging from -40°C to +50°C
(-40°C to +45°C for ERS4 347-480V fixtures) and to be
mounted horizontally to a vertical pole with LEDs
facing down, as shown.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class [A] RFLD complies with the Canadian standard ICES-003.
Ce DEFR de la classe [ A ] est conforme à la NMB-003 du Canada.
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - LED Roadway Light

Scalable Fixtures (ERS3 & ERS4)Evolve™ LED Roadway LightBEFORE YOU BEGINRead these instructions completely and carefully.Save these instructions f

Seite 2 - HANDLING

MONTAGEM3Instalação no braço de montagem da luminária com 4 parafusos posicionadores deslizantes e uma porta de fundo:• Remover a porta do alojamento

Seite 3 - PHOTOELECTRIC CONTROL

FIAÇÃO5• OBSERVAÇÃO: Fazer todas as conexões elétricas de acordo com o Código elétrico nacional dos EUA e quaisquer exigências de códigos locai

Seite 4 - MODULE DOOR

Essas instruções não têm a intenção de cobrir todos os detalhes ou variações de equipamentos, nem de abranger toda e qualquer contingência passível de

Seite 5 - AVANT DE COMMENCER

Artefactos adaptables (ERS3 & ERS4)Luminaria LED para vía pública Evolve™GELightingGuía de instalaciónGEH-6012Bimagination at workESPECIFICACION

Seite 6 - Verrou de porte

MONTAJE3Instalación en el brazo de montaje para luminaria con 4 pernos de posicionador deslizante y una puerta trasera:• Retire la puerta de alimen

Seite 7 - O V c.c. (-) Fil gris

CONEXIONADO5• NOTA: realice todas las conexiones eléctricas con forme al Código Eléctrico Nacional de los EE. UU. y a todo requisito de código l

Seite 8 - COMMANDE PHOTOÉLECTRIQUE

Estas instrucciones no pretenden cubrir todos los detalles o variaciones en los equipos, ni contemplar toda posible contingencia a encontrar en relaci

Seite 9 - Luminária viária Evolve

MOUNTING3Installation to Mounting Arm for Luminaire with 4 Slip fitter Bolts and One Bottom Door:• Remove Power door by loosening captive screw, re

Seite 10 - MANUSEIO

WIRING5• NOTE: Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements inc

Seite 11 - N/L2 Linha baixa/Neutro

These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connectio

Seite 12 - ARMAZENAGEM

Appareils d’éclairage évolutifs (ERS3 & ERS4)Luminaire routier à DEL Evolve™GELightingGuide d’installationGEH-6012Bimagination at workSPÉCIFICATI

Seite 13 - Luminaria LED para vía

ASSEMBLAGE3Installation sur bras de montage pour luminaire avec 4 boulons de joint coulissant et une porte inférieure• Desserrez la vis imperdable su

Seite 14 - Puerta de

CÂBLAGE5• REMARQUE: Toutes les connexions doivent être conformes aux normes électriques nationales et à la réglementation locale en vigueur (co

Seite 15 - CONEXIONADO

Ces instructions ne prétendent pas couvrir tous les détails et toutes les variations de l’équipement ni s’appliquer à toutes les circonstances possib

Seite 16 - SPANISH / ESPAÑOL

Estruturas escalonáveis (ERS3 & ERS4)Luminária viária Evolve™ LEDGELightingGuia de instalaçãoGEH-6012Bimagination at workESPECIFICAÇÕES• Peso: P

Kommentare zu diesen Handbüchern

Keine Kommentare