WIRING
5
NOTE: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements including grounding.
NOTE: Verify that supply voltage is correct by
comparing it to nameplate.
PHOTOELECTRIC CONTROL
6
When used, photoelectric (PE) receptacle should be
oriented so that the word “North” is directed toward
true north.
WARNING
Under no conditions should bolts be torqued to level greater
than
20 ft-lbs. (27.17 N-m)
CAUTION
Risk of injury. LED light source achieves full intensity
immediately upon being powered on. Do not look directly
at LED light source while energized.
If more upward tilt of front of luminaire is needed, first
loosen front two bolts slightly, lift luminaire and
re-snug the back two.
If downward tilt is needed, reverse procedure by
loosening back two bolts first.
Once proper level has been achieved, tighten each
bolt to 17-19 foot-pounds (23.05-25.76 N-m),
alternating front to back along diagonal of bracket as
shown in Figure 1.
IEC Units:
Terminals are readily accessible on terminal board
and will accept service leads ranging in size from
AWG No. 16 through No. 6.
Service leads (See fixture labeling for supply wire
temperature rating) should extend through mounting
bracket approximately 7 inches.
Attach service leads to terminal board as shown on
luminaire nameplate.
See table below for screw torques (See Table 1).
Dimming Control Connections (See Table 2).
A wiring diagram is provided on a label in luminaire.
FIGURE 1
TABLE 1. Terminal Board Torque Table UL Units
Wire Range Copper Aluminum Torque (in lbs)
10 - 16 SOL, STR 30
8 - 6 SOL, STR STR6 SOL, STR 45
TABLE 2. Dimming Control Connections
O VDC (-) Gray Lead
Up to 10 VDC (+) Violet Lead
IEC Units:
Power supply cable and dimming control cable (if
necessary) must be provided by customer.
Power supply cable (each conductor: phase, neutral
and ground) should be maximum of 12AWG (2.5mm
2
)
and minimum of 16 AWG (1.5mm
2
) solid or
stranded
with an overall cable diameter within the range of 7-12mm.
Dimming control cable (0 to 10 VDC) (each conductor:
positive and negative) should be 18 AWG (1.0mm
2
)
solid or stranded with an overall cable diameter
within the range of 5-10mm.
Terminal Board Connections:
Terminal Board Position Supply Type
L1 High Line
G Ground
N/L2 Low Line/Neutral