5
High Capacity with Optimal Low-End Control
Valve Size V-0 Control Valve (Degrees Open)
(in) (mm) 10 20 30 40 50 60 70 80 90
1 25 0.2 1.2 2.9 5.2 8.2 12.1 17.3 25.6 55.0
1.5 40 0.4 2.7 6.5 11.9 18.8 27.5 39.4 58.1 125
2 50 0.5 3.7 8.8 16.1 25.5 37.4 53.5 79.0 170
3 80 1.3 9.4 22.9 41.8 66.0 96.8 138.6 205 440
4 100 2.2 15.9 38.5 70.3 111 163 233 344 740
6 150 3.8 26.9 65 119 188 275 394 581 1250
8 200 5.6 40 97 177 279 409 586 865 1860
10 250 9 64.9 157 287 453 664 951 1404 3020
12 300 13.2 95 229 418 660 968 1386 2046 4400
Valve Size V-0 Control Valve (Degrees Open)
(in) (mm) 10 20 30 40 50 60 70 80 90
2 50 0.3 4.7 12.7 23.3 39.0 58.2 81.5 112 163
3 80 1.5 7.4 22.3 44.6 73.7 114 164 242 372
4 100 2.3 17.3 40.3 74.2 121 178 247 371 575
6 150 4.6 30.2 78.9 148 231 331 463 664 1160
8 200 5.7 47.8 120 225 354 512 749 1180 1770
Flanged Body Design (Available in Classes 150 and 300)
Flangeless Body Design (Available in Classes 150, 300 and 600)
Degrees Travel (Open)
Capacity Curve for 6” (150 mm) Flangeless V-0
0
10
30
40
0
20 50
60 70
80 90
1200
1000
800
600
400
200
Flow Coefficient (Cv)
High Rangeability
The V-0 Control Valve offers a modified equal percentage capacity curve
allowing optimal control at both the low end and high wide-open capacity
Kommentare zu diesen Handbüchern