Control Module Wiring Scheme
Each 14” wireless control / occupancy sensor module will power up to 48 ft. of xtures (maximum 24 ft. per side). Note: The xtures
between control sections must not be connected to each other. Power drops must be connected to the control modules.
Wireless control /occupancy sensor module The control module is attached the same as the continuous
run xtures.
NOTE: drawing not to scale
Power drop
Control section 1 Control section 2
Power drop
Etc.
Start of run
DO NOT connect the two xtures
at the end of each control section.
The xtures will not function
properly if they are connected to
multiple control modules.
Wireless control/occupancy sensor module 8 ft. xture
Troubleshooting
Symptom Solution
Luminaire will not turn on. • Check that the color of the supply side wires match the color of the wires they are connected to.
• Check that all wire connectors are properly connected.
• Verify that your input voltage is within specs.
• If you are using any additional controls IE wireless controls // motion sensors, please also verify that
those are working properly and that the unit is setup to interface with the controllers.
Mounting bracket slides
from side to side.
• Check that the mounting bracket is properly tightened using the adjustment screws provided.
ALB003-091114
GE Lighting • 1-888-MY-GE-LED (1-888-69-43-533) • www.gelighting.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo, and Albeo are trademarks of the General Electric Company.
© 2014 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Control Module Installation and Wiring
The 14” wireless control /occupancy sensor module can be installed inline with any xture conguration. The contractor must drop
power down to this module and connect any desired adjacent xtures to the module. Note: The occupancy sensor shown in these
images may differ from the actual unit provided.