GEH-5905
INSTRUCTIONS
Dimension
TM
1000 Luminaire
READ THOROUGHLY BEFORE INSTALLING
GENERAL
This luminaire is designed for outdoor lighting
applications, and should not be used in areas of limited
ventilation, or in high ambient temperature enclosures; it
should be installed and maintained according to following
recommendations.
UNPACKING
This luminaire has been properly packed so that no parts
should have been damaged during transit. Inspect to
confirm.
INSTALLATION
To install, it is necessary to open the luminaire. A flat
blade screw driver, socket wrenches for 1/4, 5/16, 3/8, and
9/16 hex-head bolts are required.
Make reflector aiming and wiring adjustments prior to
mounting the luminaire on the pole. Power leads should be
pulled as mounting parts are assembled.
REFLECTOR AIMING ADJUSTMENT
Reflectors can be rotated to any of four beam aiming
positions by removing the screws holding the reflector to
the reflector plate, rotating the reflector into the desired
position, and replacing the screws. Take care in replacing
the reflector plate so that the lamp socket leads are not
pinched between the plate and the housing. (See Figure 1)
WIRING AND WIRING ADJUSTMENTS
Make all electrical connections in accordance with
the National Electrical Code and any applicable
local code requirements.
Verify that supply voltage is correct by comparing it
to nameplate.
If unit is designated as multivolt or multiwatt,
follow specific instruction.
Do not remove insulated connectors from wires not
needed for required voltage connection.
Terminal Board will accept power leads from AWG No.
14 through No. 6 wire size.
IF SINGLE VOLTAGE:
All single voltage ballasts are pre-wired such that user
need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal to
the desired voltage terminal as indicated on the ballast
terminal nameplate.
Figure 1
WARNING
Risk of electric shock
Turn power off before servicing
see instructions
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred
to GE Lighting Solutions.
g
GE
Lighting Solutions
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - 1000 Luminaire

GEH-5905INSTRUCTIONSDimensionTM 1000 LuminaireREAD THOROUGHLY BEFORE INSTALLINGGENERALThis luminaire is designed for outdoor lightingapplications, and

Seite 2 - MOUNTING

IF MULTIWATT:Multiwatt ballasts are available in various combinationsof wattage. See wiring instructions on wiring tag insidethe luminaire.LAMP INSTAL

Seite 3 - Luminaires Dimension

GEH-5905INSTRUCTIONSLuminaires DimensionTM 1000LIRE ATTENTIVEMENT AVANT D'INSTALLERGÉNÉRALITÉSCe luminaire a été conçu pour une utilisation à l&a

Seite 4 - ATTENTION

35-201578-8Z (8/03)APPAREILS À PUISSANCES MULTIPLESDes ballasts à puissances multiples sont disponibles avecdiverses combinaisons de puissance. Consul

Kommentare zu diesen Handbüchern

Keine Kommentare