GE EPST Installationsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
NOTE: Make all electrical connections in accordance
with the National Electrical Code and any applicable
local code requirements.
NOTE: Verify that supply voltage is correct by
comparing it to nameplate.
Standard Mounting
Remove cover at base of unit and connect all 3 power
leads to the terminal block.
Replace cover.
Pendant Mounting
Remove one screw to open the top of the xture.
Allow the bottom to hang from it’s hinges.
Pull the wires into the top housing.
Connect all 3 power leads to the terminal block in the
top housing.
Close top and replace the latch.
WIRING
3
UNPACKING
MOUNTING
This luminaire has been properly packed so that no
parts should have been damaged during transit.
Inspect to conrm.
1
2
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Follow installation instructions.
WARNING
Risk of injury. LED light source achieves full intensity
immediately upon being powered on. Do not look
directly at LED light source while energized during install.
Standard Mounting
This luminaire is provided with means for mounting on
3-inch (76mm) max. outside diameter pole tops.
Feed the power supply leads through the sliptter wire
access hole as the xture is installed on the pole.
Orient canopy screw or latch toward street and level
by adjusting the 3 screws, and tighten.
Caution: Tighten screws to 15 - 20 ft-lbs (20-27 N-m).
Remove shipping ties from wire way in the rear upright.
Pendant Mounting
Use 1 1/4 inch pipe for Pendant.
Insert the pendant pipe through the cupola.
Apply an appropriate pipe sealant to the end of the
pendant pipe.
Turn the pendant pipe into the 1 1/4 inch pipe tting
on top of the xture.
Orient the xture so that the house side faces the
proper direction.
Tighten the top set screw on the pipe tting.
Fit the cupola onto the top housing of the xture.
Tighten the 3 cupola screws.
Customer Pendant
Apply pipe sealant to
this joint
Set Screw
Cupola
Pipe Fitting
Cupola Screws (3)
Latch Screw
Latch
GE_GEH6005A_LED_Evolve_EPST_PostTop_Salem_Installation_FINAL_091113.indd 2 9/11/2013 9:52:55 AM
Seitenansicht 1
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare