PB3-POS-RP ProBridge User Manual

Seite 2

PB3-POS-RP ProBridge User Manual 10 PB3-POS-RP ProBridge includes: • (1) PB3-POS-RP ProBridge unit. • (1) P/N 4310-0034B: RJ45 to RJ45 cable. Conne

Seite 3 - TABLE OF CONTENTS

11 Moisture: Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.

Seite 4

PB3-POS-RP ProBridge User Manual 124310-0007 120VAC Power Supply Power Supply Input Voltage: 120 VAC Tolerance: ±10% Frequency: 60 Hz Power Supply

Seite 5 - Before You Begin

13 Installation Before installation please familiarize yourself with the PB3 and its typical system layout. PB3 Components Figure 2-1. ProBridge C

Seite 6

PB3-POS-RP ProBridge User Manual 14Typical System Layout DVMRe TriplexCBR-PB3-RPProBridge2ndCBR-PB3-RPProBridgeCameraCamera**RS485 Cable(Supplied by

Seite 7 - Introduction

15 Required Dip Switch Information SW1 Dipswitch 1-4 Special Functions (See Section 3) Dipswitch 5-8 Camera Assignment* SW2 Dipswitch 1 R

Seite 8 - Disclaimer

PB3-POS-RP ProBridge User Manual 16Switch Settings as shown above are: • Camera Number 1 (SW1 5-8) • Generic Printer (SW3 1-8) • PB3 Termination OF

Seite 9 - PB3 System Components

17 6) If more than one cash register interface is to be installed repeat steps 1-4 above for each additional cash register. 7) Connect each PB3 uni

Seite 10 - Installation Environment

PB3-POS-RP ProBridge User Manual 18If the unit fails to display transaction text, please go to the troubleshooting section of this manual.

Seite 11

19 Dip Switch Settings This chapter deals in detail with the Dip Switch Settings. The PB3 must be re-initialized before any changes to the switch set

Seite 12

PB3-POS-RP ProBridge User Manual 2 Copyright Copyright © 2006, GE Security, Inc. All rights reserved. This document may not be copied in whole or

Seite 13 - Installation

PB3-POS-RP ProBridge User Manual 20Demo Mode (Simulated Message) This setting permits the PB3 to send a simulated POS transaction message to the DVMRe

Seite 14 - Typical System Layout

21 SW1 - Switches 5-8 Dipswitches 5 thru 8 on SW1 assigns transaction text for that cash register’s PB3 unit to a specific camera on the DVMRe. Came

Seite 15

PB3-POS-RP ProBridge User Manual 22SW2 Settings SW2 - Switch 1 Switch 1 on SW2 is reserved for Technical Support personnel. Do not use. SW2 - Switche

Seite 16 - Detailed Installation Steps

23 SW2 - Switches 5-8 Switches 5-8 on SW2 are used to modify the communication transfer protocol on Port 2 of the PB3 should the POS device you are u

Seite 17 - Verify Operation

PB3-POS-RP ProBridge User Manual 24SW3 Settings SW3 - Switches 1-8 Switches 1 thru 8 on SW3 define the serial device used for the interface. The se

Seite 18 - PB3-POS-RP ProBridge

25 SW3 Printer 1 2 3 4 5 6 7 8 Serial DA U U U U U U U U Generic U U U U U U U D Citizen POS U U U U U U D U Epson TM88 U U U U U U D D P

Seite 19 - Dip Switch Settings

PB3-POS-RP ProBridge User Manual 26SW4 Settings SW4 – Switches 1,2, 4-6 These switches are reserved for Technical Support personnel. Do not use. SW4

Seite 20

27 Troubleshooting Problem Probable Cause Solution *Unable to verify capture of text. 1. No power. 2. Incorrect cabling. 3. Incorrect switch settin

Seite 21 - SW1 - Switches 5-8

PB3-POS-RP ProBridge User Manual 28Hyperterminal Setup Manual configuration can also be completed using Windows HyperTerminal in stead of the DIP swit

Seite 22 - SW2 Settings

29 Figure 5-1. Laptop connected to PB3 running HyperTerminal. Open a new Connection (FILE>NEW): Give the connection a name and select an Icon.

Seite 23 - SW2 - Switches 5-8

3 TABLE OF CONTENTS BEFORE YOU BEGIN...5 INTRODUCTION...

Seite 24 - SW3 Settings

PB3-POS-RP ProBridge User Manual 30The Com1 Properties menu will appear. Select the following settings to complete the setup: Bits per Second = 57600

Seite 25

31 The configurable settings are: • Protocol • Baud Rate • Parity • # of Stop Bits • Character Set • POS Device Type Once HyperTerminal mode

Seite 26 - SW4 Settings

PB3-POS-RP ProBridge User Manual 32 Main Menu Option 2 (Port #2) Port #2 is an RS-232 port that connects the PB3 unit to the serial device Interconne

Seite 27 - Troubleshooting

33 Menu Selection 2 – Protocol Options • Asynchronous Menu Selection 3 – Baud Rate Baud Rate is only used if Protocol option selected is Asynchronou

Seite 28 - Hyperterminal Setup

PB3-POS-RP ProBridge User Manual 34Menu Selection 6 – Code (Character) The available selections are: • 7-Bit ASCII • 8-Bit ASCII Menus Selection 7

Seite 29

35 Main Menu Option 3 (Text Setup) The Text Setup menus allow the user to use some text filtering options. These options allow the user to filter out

Seite 30

PB3-POS-RP ProBridge User Manual 36 Bypass Count The Bypass Count is the number of characters to bypass or ignore excluding the characters in the Text

Seite 31

37 Linefeed), the PB3 will output both a Carriage Return and a Line Feed. If this option is disabled then, the PB3 will not append any extra charact

Seite 32 - Main Menu Option 2 (Port #2)

PB3-POS-RP ProBridge User Manual 38 An example of the setup above is shown in the following illustration. ReceiptData stored on HDText StringBypass C

Seite 33 - • Even

39 Main Menu Option 4 (Alarm Setup) Use this option to enable or disable alarm mode and to customize the text to display for each alarm. Select optio

Seite 34

PB3-POS-RP ProBridge User Manual 4VERIFY OPERATION... 17 DIP SWITCH SETTINGS ...

Seite 35

PB3-POS-RP ProBridge User Manual 40PB3 Specifications Physical Housing Metal enclosure. Dimensions (W x L x H) 4.0 x 7.0 x 1.0” (100 x 175 x 2

Seite 36

41 Cable Specifications ProBridge to Triplex (DVMRe-CT) RJ45 Connector RJ45 Connector Part Number : 4310-0034B Communication Type: RS232 Connector

Seite 37

PB3-POS-RP ProBridge User Manual 42ProBridge to DVMRe (DVMRe-CD/S) RJ45 ConnectorDB9F Part Number : 4310-0047B Communication Type: RS232 Connector T

Seite 38 - Data stored on HD

43 ProBridge to ProBridge Cable RJ45 Connector RJ45 Connector Part Number : Installer Provided Communication Type: RS-485 Connector Type: RJ45, R

Seite 39 - Main Menu Option 4 (Backup)

PB3-POS-RP ProBridge User Manual 44ProBridge to Printer Interconnect Cable DB9FDB25M Part Number : 4310-0069A Communication Type: RS232 Connector Ty

Seite 40 - PB3 Specifications

45 ProBridge Interconnect Cable to serial device DB25MDB25F DB25F Part Number : 4310-0068A Communication Type: RS232 Connector Type: DB25M, DB25F,

Seite 41 - Cable Specifications

PB3-POS-RP ProBridge User Manual 46Triport Cable The Triport cable is used for tapping serial RS-232 ports available on most POS cash registers. The

Seite 42 - RJ45 Connector

47 Triport Cable Modifications In some cases, it may become necessary to modify the wiring of the Triport cable. It is recommended that only trained

Seite 43 - RJ45 Connector RJ45 Connector

PB3-POS-RP ProBridge User Manual 48Contacting technical support For assistance installing, operating, maintaining, and troubleshooting this product, r

Seite 44

5 Before You Begin Read these instructions before installing or operating this product. Note: This installation should be made by a qualified service

Seite 45 - DB25F DB25F

PB3-POS-RP ProBridge User Manual 6 * WARNING: Improper use of this equipment can cause severe bodily injury or equipment damage. ** CAUTION: Imprope

Seite 46 - Triport Cable

7 Introduction This manual provides all the information necessary to properly install this product. ** CAUTION: Your system’s layout, camera assignm

Seite 47

PB3-POS-RP ProBridge User Manual 8Compatibility The PB3 is compatible with the following GE DVMRe products: DVMRe Type Software Version PPC Version

Seite 48 - Contacting technical support

9 with specific cameras. GE assumes no responsibility for the amount and type of information available, the operation, non-operation or erroneous op