Seitenansicht 0
I-184/2008
Most commonly ordered
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
GH5 GHB
®
LUMINAIRE
High Bay, Open — Bracket Mount Optical Series
APPLICATIONS
For over 20 ft. (6 meter) applications, warehouses, assembly plants, material handling,
maintenance areas, manufacturing inspection areas, hangars, and other areas where
economics and energy-ecient light sources are important
1598 Listed
Suitable For Damp Locations
Listed to Canadian
standards and codes
55° C ambient, standard
Threaded slide-in mounting
adapter for easy mounting
Flexible Spacing Criterion
(SC) – ve-position mounting
bracket allows eld-
adjustable light distribution
In-line EZ Connect
plug-in
adapter port allows for:
• hook/loop, cord & NEMA plug
• plug-in diagnostics capability
plug-in modular wiring systems
• plug-in fuse kits
Symmetrical heavy-duty
die-cast aluminum ballast
housing with electrocoat gray
or white polyester paint nish
Mogul base socket -E39
standard
ORDERING NUMBER LOGIC
GH5
PRODUCT
IDENT
XXX
G
COLOR
X
40
WATTAGE
XX
E
LIGHT
SOURCE
X
0
VOLTAGE
X
A
BALLAST
TYPE
X
V6
OPTICAL
CODE
XX
NA
PHOTOMETRY
CODE
XX
11
MOUNTING
CODE
XX
B
OPTIONS
X
V6 = Open
ventilated
16-inch
Reector.
(Do not
use open
optical
with lamps
marked
for use in
enclosed
xtures
only.)
D6 = 16-
inch
Reector
with door
glass kit
included.
(Note: See
table for
door glass
limitations)
NA = Not
Applicable
(Reector
position is
set at
installation)
XX = Select Code Below
11 = Pendant mounting
13 =
Provision for Slide-on Primary Electrical
Disconnect. Order TWOBP Box (Thru
Feed Capability Only) Separately.
14 =
Provision for Slide-on Primary Electrical
Disconnect. (Pendant and Thru Feed
Capability) Order PED Box Separately
15 = Prewire with EZ-Loop, Cord and Plug
Part of “Power Hook”. Order
Receptacle/Hook Box Separately.
(Not CSA/CUL)
31 = Prewire with EZ-Hook, 3-ft (0.9
Meters)
#16/3 Cord, and Nema Plug
33 = Prewire with EZ-Loop, 3-ft (0.9 Meters)
#16/3 Cord, and Nema Plug
(Order locking receptacle hook box
separately.)
MODULAR PREWIRE
41 = ACS with 3-ft (0.9 meter) cord & EZ-Hook
69 = ACS with 6-ft (1.8 meter) cord & EZ-Hook
43 = ACS with 3-ft (0.9 meter) cord & EZ-Loop
70 = ACS with 6-ft (1.8 meter) cord & EZ-Loop
PLUG-N-GO
51 =
Plug-N-Go with 3 ft. (0.9 meter) Cord & Hook
71 =
Plug-N-Go with 6 ft. (1.8meter) Cord & Hook
53 =
Plug-N-Go with 3 ft. (0.9 meter) Cord & Loop
72 =
Plug-N-Go with 6 ft. (1.8 meter) Cord & Loop
Note: ACS = Flex 3+
Plug-N-Go = FSC Series
B = Time Delay
Automatically
Switch Quartz
F = Fusing
G = Secondary
Wiring Access.
7/8 in. dia.
knockout
K = Encapsulated Ballast
(For use with 250 &
400 watt Auto Reg
Ballast only)
Q = Non-Time Delay
Automatically
Switch Quartz
R = Non-Switched
Quartz.
S = Exclusionary mogul
base socket for MH
open xtures
SPECIFICATION FEATURES
350,400 EPMH 1.2 1 179646 V6 NA
400 EPMH 1.5 2* 179642 V6 NA
400 EPMH 1.7 3* 179643 V6 NA
400 EPMH 2.0 4* 179644 V6 NA
400 EPMH 2.3 5* 179645 V6 NA
350,400 EPMH (Coated) 1.1 1 179647 V6 NA
400 EPMH (Coated) 1.3 2* 179648 V6 NA
400 EPMH (Coated) 1.5 3* 179649 V6 NA
400 EPMH (Coated) 1.6 4* 179650 V6 NA
250,400 HPS 1.0 3 179639 V6 NA
250,400 HPS 1.1 4 179640 V6 NA
250,400 HPS 1.4 5 179641 V6 NA
* Cannot use with door glass accessory
V6 OPTICAL - Open 16 in. Reector
Light Spacing Reector Photometric Optical
Photometry
Wattage Source Criteria Position Curve Code Code
PHOTOMETRIC SELECTION TABLE
With
EZ Connect
TM
Single casting integral
hook/loop and mounting
plate is available
Safety chain provisions
Shipped as components:
Ballast, Optical.
Magnapack available
for ballast.
GH5 = GHB
Luminaire
G = Gray
Electro
Coat
W = White
Polyester
Powder
17 = 175
20 = 200
25 = 250
32 = 320
35 = 350
40 = 400
E = Energy
Act Compli-
ant Pulse MH
(EPMH)
S = HPS
For
International
Markets only
M = MH
P = Pulse
Start
MH
Note: Lamp is
vertical base
up. Lamp not
included.
60Hz
0 = 120/208/
240/277
MULTIVOLT
1 = 120
2 = 208
3 = 240
4 = 277
5 = 480
D = 347
F = 120X347
T = 220
50Hz
6 = 220
R = 230
Y = 240
G = 380
See
Ballast
Selection
Table
A =
Autoreg
D =
System 3
Bilevel
Autoreg
(See
Technical
Section)
H = HPF
Reactor
or Lag
L = Super
Low Loss
Autoreg
D6 OPTICAL - Ventilated 16 in. Reector with Flat Clear Door Glass
D6 Light Spacing Reector Photometric Optical
Photometry
Wattage Source Criteria Position Curve Code Code
175 EPMH 1.1 5 179651 D6 NA
250 EPMH 1.1 5 179651 D6 NA
175,250 EPMH 1.1 5 179651 D6 NA
320*
(ED28) EPMH 1.1 5 179651 D6 NA
350 EPMH 1.1 1 450780 D6 NA
350 EPMH(Coated) 1.1 1 450782 D6 NA
400 EPMH 1.1 1 450780 D6 NA
400 EPMH(Coated) 1.1 1 450782 D6 NA
N/A = Not Available
* 320 watt, ED28 pulse start MH
PHOTOMETRIC SELECTION TABLE
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - LUMINAIRE

I-184/2008 Most commonly orderedGE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com1 - 8 8 8 - 6 9 - 4 3 - 5 3 3GH5 GHB® LUMINA

Seite 2

2008/I-185GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com1 - 8 8 8 - 6 9 - 4 3 - 5 3 3DATAApproximate Net Weight lbs kgs

Kommentare zu diesen Handbüchern

Keine Kommentare