GE JV247PWW Bedienungshandbuch Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
BEFORE YOU BEGIN
Installation Range Hood
Instructions
Read these instructions completely and carefully.
IMPORTANT – Save these instructions for
local inspector’s use.
IMPORTANT – Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions
for future reference.
• Skill level – Installation of this appliance requires
basic mechanical and electrical skills.
• Completion time – 30 minutes–3 hours
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
NOTE: Read the ductwork sections only if you do not
have existing ductwork. If you have existing ductwork,
skip to the “Damage” section and proceed.
WARNING – TO REDUCE THE RISK OF FIRE AND
723523(5/<(;+$867$,5%(685(72'8&7$,52876,'(³
DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR
CEILINGS OR INTO ATTICS, CRAWL SPACES OR GARAGES.
7KHYHQWLQJV\VWHPPXVWH[KDXVWWRWKHRXWVLGH
This hood can be vented vertically through upper cabinets or
horizontally through an outside wall. Ductwork is not included.
Exhaust connection:
7KHKRRGH[KDXVWKDVEHHQGHVLJQHGWRPDWHZLWK
standard 3
1
ø4s[s rectangular ducting or 7s diameter
round ducting.
If a 6s round duct is required, a rectangular-to-round
transition adaptor must be used*. Do not use less than a
6s diameter duct.
Maximum duct length:
For satisfactory air movement, the total duct length
of a 3
1
ø4s[s rectangular, 6s or 7s diameter round
duct should not exceed 65 equivalent feet. See
the WORKSHEET–CALCULATE TOTAL EQUIVALENT
DUCTWORK LENGTH section.
NOTE: It is important that ducting be installed using the
most direct route and with as few elbows as possible.
7KLVHQVXUHVFOHDUYHQWLQJRIH[KDXVWDQGKHOSVSUHYHQW
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts. When applicable, install any
makeup (replacement) air system in accordance with local
building code requirements. Visit GEAppliances.com for
available makeup air solutions.
Elbows, transitions, wall and roofcaps, etc.,
present additional resistance to airflow and are equivalent
to a section of straight duct longer than their actual
physical size. When calculating the total duct length, add
the equivalent lengths of all transitions and adaptors plus
the length of all straight duct sections. The charts on the
following pages show you how to calculate total equivalent
GXFWZRUNOHQJWKXVLQJWKHDSSUR[LPDWHIHHWRIHTXLYDOHQW
length of some typical ducts.
DUCTWORK REQUIREMENTS
WARNING – Before beginning the
installation, switch power off at service panel and
lock the service disconnecting means to prevent power
from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the
service panel.
FOR YOUR SAFETY:
Questions? Call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com
An optional Power Cord Connection Kit, model JXHC1,
LVDYDLODEOHDWH[WUDFRVWIURP\RXU*(VXSSOLHUIRU
installation using a standard 3-prong, grounded wall
outlet. Follow the Installation Instructions packed with
the kit to connect the power cord to the range hood.
OPTIONAL POWER CORD KIT JXHC1
6
* IMPORTANT: If a rectangular-to-round
transition adaptor is used, the bottom
corners of the damper will have to be
cut to fit, using the tin snips, in order
to allow free movement of the damper.
Equivalent lengths of duct pieces
are based on actual tests and reflect
requirements for good venting
performance with any hood.
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10 11 ... 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare