Ge GFK-2193A Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Ge GFK-2193A herunter. GE GFK-2193A User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - GE Fanuc Automation

GE Fanuc Automation Programmable Control Products Series 90™-30 PROFIBUS Slave Module User's Manual GFK-2193A August 2004

Seite 2 - Caution

GFK-2193A 2-1 Installation This chapter contains information on the following procedures:  Reviewing system power requirements  Instal

Seite 3 - Contents

2-2 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 2 Connecting the Slave to the PROFIBUS Network Network Se

Seite 4

GFK-2193A Chapter 2 Installation 2-3 2 PROFIBUS Cable Types The recommended cable is  Belden 3079A PROFIBUS Cable This is a shielded, 150

Seite 5

2-4 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 2 Note: For proper network termination, it is essential

Seite 6 - PROFIBUS DP

GFK-2193A 3-1 Configuration These configuration procedures are intended for users with at least a basic knowledge of the CIMPLICITY Machin

Seite 7 - Bus Communication

3-2 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 3 Configuring a PROFIBUS Slave Module The PROFIBUS Slave

Seite 8 - Network Topology

GFK-2193A Chapter 3 Configuration 3-3 3 Input Data Area Tab The input data area describes data received over the network by the Slave module f

Seite 9 - Network Connectors

3-4 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 3 Output Data Area Tab The output data area describes dat

Seite 10 - Chapter

GFK-2193A 4-1 Status and Diagnostics The following methods can be used to obtain status and diagnostic data:  Observing and interpreting

Seite 11 - Network Segment Length

4-2 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 4 Status/Firmware ID Array The starting reference address

Seite 12 - Network Termination

GFL-002 Warnings, Cautions, and Notes as Used in this Publication Warning Warning notices are used in this publication to emphasize that hazardous

Seite 13 - Network Baud Rate

GFK-2193A Chapter 4 Status and Diagnostics 4-3 4 Enable Input Command Block PointerRack/Slot Location Task #Fault OutputCOMM_REQIN FTSY

Seite 14

4-4 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 4 FT Output: The function’s FT (fault) output can provide

Seite 15 - Settings Tab

GFK-2193A Chapter 4 Status and Diagnostics 4-5 4 COMMREQ Programming Requirements and Recommendations  COMMREQ instructions should be enable

Seite 16 - Input Data Area Tab

4-6 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 4 COMMREQ Status Word The following table defines the for

Seite 17 - Output Data Area Tab

GFK-2193A Chapter 4 Status and Diagnostics 4-7 4 PROFIBUS Slave Module COMMREQ Reference The PROFIBUS Slave module supports the following COMM

Seite 18

4-8 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 4 (Word 7) Command Code: Word 7 specifies the Command co

Seite 19 - Network Parameter Errors

GFK-2193A Chapter 4 Status and Diagnostics 4-9 4 Network Parameter Errors The following errors codes may be returned in bits 0—6 in the Get Sl

Seite 20 - COMMREQ Ladder Instruction

4-10 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 4 Read Module Header (5) The Read Module Header command

Seite 21 - FT Output Truth Table

GFK-2193A Chapter 4 Status and Diagnostics 4-11 4 (Word 9) Local PLC - Memory Starting Address: Word 9 determines the starting address in the

Seite 22 - Error Detection and Handling

4-12 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2193A 4 Clear Counters (6) The Clear Counters Command sets the

Seite 23 - COMMREQ Status Word

Contents GFK-2193A iii Overview and Specifications... 1-1

Seite 24 - Get Slave Status COMMREQ (3)

Index GFK-2193A Index-1 C Clear Counters (6), 4-12 COMMREQs Clear Counters (6), 4-12 Get Slave Status details, 4-7 memory types, 4-7 PROFIBUS M

Seite 25

Contents iv Series 90™-30 PROFIBUS Slave Module User's Manual –August 2004 GFK-2193A Get Slave Status Command Block – Basic Example ...

Seite 26

GFK-2121A 1-1 Overview and Specifications This manual provides instructions for installing, programming, and troubleshooting control syste

Seite 27 - Read Module Header (5)

1-2 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2121A 1 SYS COM PROFIBUS DP SLAVE 5-IGND SERVICE RS232 PROFIBU

Seite 28

GFK-2121A Chapter 1 Overview and Specifications 1-3 1 PROFIBUS Basics PROFIBUS Network Overview • PROFIBUS is an open, vendor independent Fiel

Seite 29 - Clear Counters (6)

1-4 Series 90™-30 PROFIBUS Slave Module User's Manual – August 2004 GFK-2121A 1 Data bandwidth Demands on PROFIBUS Communications Syste

Seite 30

GFK-2121A Chapter 1 Overview and Specifications 1-5 1 Figure 1-2. Repeaters and bus termination Network Connectors PROFIB

Kommentare zu diesen Handbüchern

Keine Kommentare