M-400, M-400A Luminaires

This luminaire is designed for outdoor lighting service, and should not be used in areas of limited ventilation,
or in high ambient temperatures. Best results will be obtained if installed and maintained according to
the following recommendations.

This luminaire has been properly packed so that no parts should have been damaged during transit.
Inspect to conrm.



The bird shield behind slip tter clamp comes with an opening for 1 ¼ (1.660 OD) inch pipe. If a larger pipe
size is used, detach knockout to provide a larger opening. Insert pipe carefully through bird-shield and into
back of the luminaire until it hits stop which sticks down from top of housing.





      




Remove power module ballast door by loosening captive screw, releasing the door latch and opening door
to a vertical position. Pull out polarized disconnect plug which connects top housing wiring with ballast
door. Now grasp door securely in both hands and open door further until it comes free from hinges in top
housing. This occurs at approximately 35 degrees from vertical on pole side of hinge. In this position hinge
pins will easily slide upward out of their hinge cradles in top housing.
The pipe clamp accommodates only 2-inch pipe brackets for MDRA, MDCA and 1 ¼ inch thru 2 inch for
M4AC, M4AR models. If necessary, adjust 4 pipe clamp bolts such that opening is slightly larger than
pipe size being used.
The luminaire may be adjusted up or down with respect to pipe. A pad is provided on top of housing for
convenient application of hand level.
To mount, Insert pipe carefully through birdshield (if required) and into back of the luminaire until it hits
the leveling steps or stop that sticks down from the top of housing.
Hold luminaire approximately level and snug up bolts (4-5 foot-pounds). If more upward tilt of front of
luminaire is needed, rst loosen front two bolts slightly, lift luminaire and re-snug the back two. If downward
tilt is needed, reverse procedure by loosening back two bolts rst.


Once proper level has been achieved, tighten each bolt to 10-12 foot-pounds, alternating front to back
along diagonal of bracket as shown in Figure 1. If a torque wrench is not available, correct torque may
be achieved by turning bolts two to three full turns (or until bottoming occurs) past “snug position’’. This
should be done one turn at a time alternating in pattern according to Figure 1.




 Turn power o before servicing


 Do not touch operating luminaire


 Wear safety glasses and gloves during
installation and servicing










The pipe clamp accommodates only 2-inch pipe. If necessary, adjust 4 pipe clamp bolts such that opening
is slightly larger than pipe size being used.
The luminaire may be adjusted up or down with respect to pipe. A pad is provided on top of housing for
convenient application of hand level.
To mount, Insert pipe and into back of the luminaire until it hits the stop that sticks down from the top
of housing.
Hold luminaire approximately level and snug up bolts (4-5 foot-pounds). If more upward tilt of front of
luminaire is needed, rst loosen front two bolts slightly, lift luminaire and re-snug the back two. If downward
tilt is needed, reverse procedure by loosening back two bolts rst.
Once proper level has been achieved, tighten each bolt to 10-12 foot-pounds, alternating front to back
along diagonal of bracket as shown in Figure 1. If a torque wrench is not available, correct torque may
be achieved by turning bolts two to three full turns (or until bottoming occurs) past “snug position’’. This
should be done one turn at a time alternating in pattern according to Figure 1.








g
GE
Lighting Solutions
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information
be desired or should particular problems arise which are not covered suciently for the purchaser’s purposes, the matter should be referred to GE Lighting Solutions.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - M-400, M-400A Luminaires

M-400, M-400A LuminairesThis luminaire is designed for outdoor lighting service, and should not be used in areas of limite

Seite 2

The pipe clamp accommodates 1 1/4 inch through 2-inch pipe. If necessary, adjust the two pipe clamp bolts so that opening is slightly larger than pipe

Seite 3

M-400, M-400A LuminairesCe luminaire a été conçu pour une utilisation à l’extérieur et ne doi

Seite 4 - 

Le collier de serrage est compatible uniquement avec un tuyau de 1 ¼ po à 2 po. Si nécessaire, réglez la position des 2 boulons de colliers de serrage